PSC CIC CAMPAIGN SEP 23 TO NOV 23
Download consolidated checklist for CIC campaign:
https://drive.google.com/file/d/1PV0sx87k89fOMvCYmcy00bXX2x47ClWm/view?usp=sharing
The Member Authorities of
the Tokyo and the Paris Memoranda of Understanding (MoU) on Port State Control launched
a joint Concentrated Inspection Campaign (CIC) on Fire Safety.
The purpose of the campaign is:
• to create awareness among the ship’s crew and
owners about the importance
of fire safety measures;
• to verify that the ship complies with fire
safety requirements under the relevant IMO instruments
This inspection campaign will be held for three months, commencing from 1 September 2023 and ending 30 November 2023.
The
campaign will examine specific areas related to fire safety in conjunction with
the regular Port State Control inspection. A ship will be subject to only one inspection
under this CIC during the period of the campaign.
Watch video for more details:
Ensure your safety management system is up and running:
Almost each deficiency can be related to
the SMS onboard.
Ensure ISM is implemented
onboard
Train your crews on fire
safety issues and drills
Share this document to the
vessel for their reference and checks.
1. 1.Are the emergency escape routes maintained in a safe condition? – (07120/04103)
Checks:
Escape routes are clear of obstacles and accessible
IMO signs and marking
Main and emergency lighting is operational
Securing devices of emergency exit hatches
are opertaitonal
Incase of passenger ships, that means of
escape are marked by lighting or photoluminescent strip
2. 2.Are the fire doors in good working condition ? (07105)
Checks:
Fire control plan to identify fire door’s
class (A or B)
Actual condition of the door (for corrosion
or damage)
Test operation (local/remote) , Make sure
doors close and latch properly
Control panel indicators are functional
(passenger vessels)
Self closing fire doors are not improperly
lashed
Doors in boundary bulkheads of machinery spaces
of category A are reasonably gas tight and self closing
Modification and/or repair of fire doors,
if any has been accepted by ship’s administration
3. 3.Has the fixed fire detection and fire alarm system been periodically tested in accordance with the requirements of the administration? (07106)
Checks:
Test records for the fire detection and alarm
systems
Fire detectors and manual call points ( for
damage, obstruction or being painted over)
Control panel indicators (for faults and/or
alarms of general fire detection and fire alarm panel and repeaters)
Main and emergency power supply for control
panel
Spares should be available on board
4.
Are ventilation closing appliances capable of
being closed? (07116)
Checks:
Test ventilation closing appliances (proper
and operation)
Means of closing ventilation are accessible
(and closed from outside the space they served)
and properly marked (marking and indication open/close position)
Check that there is no presence of holes or
severe deterioration (including conditions of sealing/gaskets)
Check if the operation is not obstructed by
equipment stores or cargo
If applicaple check that battery room
ventilators are fitted with functional means of closing and provided with an
appropriate warning notice at the closing device.
5. 5.Are the means of control for power ventilation of machinery space operable from two grouped positions ? (07116)
Checks:
Means of control for power ventilation is
provided for stopping ventilating fans
Power ventilation of ER is operable from two
positions one of which shall be outside the ER
Means provided for stopping the power
ventilation of the ER are entirely separated from ventilation of other spaces
6. 6.Can each fire pump deliver at least the two required jets of water ? (07113)
Checks:
Fire pump and emergency fire pumps are
capable to deliver 7 bar pressure
Self priming available for the fire pump
Fire pumps are free from leak
Associated fittings are in good condition.
Crew familiar with the various location off
starting fire pump
7. 7.Are the means of control provided in a position outside the machinery space for stopping ventilation and oil transfer equipment operational? (07114 )
Checks:
Means of controls are accessible , not
blocked and are ready for use
Function test on a sample of the remote
means of control for stopping ventilation and oil transfer equipment
The ventilation fans and oil transfer pumps
are either stopped or their circuit breaker tripped
8. 8.Is the room for the fixed gas fire extinguishing medium used only for this purpose ? (07109)
Checks:
C O 2 rom is used for no other purposes (no
storage etc)
Structural fire protection not impaired
Emergency lights
Access to the room (key available)
Ventilation
Instructions posted, markings of
component/valves
9. 9.Are the valves used in the fire main line operational ?(07110)
Checks:
Fire main isolating valves are in good condition
For tankers the isolation valves fitted in
the fire main at poop front and on the tank deck are in good working condition
Hydrant valves are in good working
condition. No leakage should be observed from the hydrant once the valve is
completely shout
1 10,Where a fire drill was witnessed was it found to be satisfactory? (07125)
Checks:
Fire drills shall be conducted and recorded
Crew is familiar with location and
operation of fire fighting systems and appliances
The fire drill is carried out as far as
possible like a real emergency
The crew can respond in an event following
an emergency
The crew can communicate , receive and
carry out instructions efficiently
The master is in control of the emergency
and the information flow is from one central command location
To train your ship's personnel, kindly register using the following link:
MARINER UPDATE YOUTUBE LINK:
https://www.youtube.com/channel/UC1_mKAnB9da3ilj1wVuIpKQ
Mariner update telegram
Mariner update facebook
https://www.facebook.com/marinerupdate?mibextid=ZbWKwL
Mariner update Instagram
https://www.instagram.com/mariner.update
Mariner Update Linkedin
https://www.linkedin.com/company/96601411/admin/feed/posts/
Comments
Post a Comment